ANSI A161.1 PDF

Buy ANSI A PERFORMANCE STANDARDS FOR KITCHEN AND VANITY CABINETS from SAI Global. Buy KCMA A Performance And Construction Standard For Kitchen And Vanity Cabinets from SAI Global. Kitchen and vanity cabinets bearing the ANSI/KCMA A certification seal have been extensively tested for their structural integrity, drawer.

Author: Kezshura Akilrajas
Country: Saudi Arabia
Language: English (Spanish)
Genre: Video
Published (Last): 7 November 2011
Pages: 409
PDF File Size: 9.15 Mb
ePub File Size: 16.66 Mb
ISBN: 777-9-28349-155-2
Downloads: 59087
Price: Free* [*Free Regsitration Required]
Uploader: Arashijar

Mastercraft Cabinets | KCMA Certification Program, ANSI Standards

The weighted door is a161.11 operated for 10 cycles from 90 degrees open to 20 degrees open, and returned to the degree position. On all cabinets, the shelves and bottoms are loaded at 15 pounds per square foot, with the weight maintained for seven anso to ensure that there is no excessive deflection and no visible sign of joint separation or failure of any part of the cabinets or the mounting system. Finish is exposed to vinegar, grape juice, olive oil, lemon juice, proof alcohol and more to ensure no appreciable discoloration, stain or whitening of the finish occurs.

For information on the certification or to locate a certified cabinet manufacturer, visit the Certifications portal at KCMA. Drawers and drawer mechanisms are tested at 15 pounds per square foot and operated through 25, opening and closing cycles to assure durability.

A 3 pound weight is dropped 10 times against the drawer assembly to ensure that the drawer front assembly will withstand the impact of closing. These include participation and review by consumer and supplier organizations, builders, remodelers, the U.

The strength behind certified cabinetry: ANSI/KCMA A | Woodworking Network

To test the ability of shelves, bottoms and drawer bottoms to withstand the dropping of cans and other items, a 3-pound steel ball is dropped from 6 inches above the surface. Installed wall cabinets are loaded with pounds to ensure that the cabinet will accept net loading in compliance with ANSI A Skip to main content. To test the ability of the finish to withstand high heata cabinet door is placed in a hotbox at F and 70 percent anxi humidity for 24 hours.

  EVOLVE BLADE DUALCORDER HD MANUAL PDF

Have something to say? Cabinet finishes are inspected to ensure that stringent standards of appearance are also met.

The strength behind certified cabinetry: ANSI/KCMA A161.1

View the discussion thread. KCMA has sponsored the nationally recognized cabinet testing and certification program for more than 45 years. To be certified, cabinetry must first meet the following 14 construction requirements: Your Email has been successfully sent! A load of up to pounds is applied against the inside of cabinet fronts to ensure reliable front joints. To test the strength of base-front joints, a load of pounds is applied against the inside of cabinet-front stiles for cabinets with a drawer rail, or pounds for cabinets without a drawer rail, to ensure reliable front joints that will not open during stress in service or during installation.

Cabinet doors are weighted with 65 pounds and operated 10 times to test the ability of door and hinges to withstand loading. The cabinet door must operate as before the test and show no damage or sign of separation or failure in the system.

To test the ability of doors, hinges, and means of attachment to withstand loading, a611.1 pounds of weight is applied on the door. A 3 pound steel ball is “drop tested” against shelves, cabinet bottoms and drawer bodies to ensure cabinets will withstand dropping of cans and other items.

  ELRIC STEALER SOULS PDF

Scroll Down for more stories. After 10 drops, there must be no evidence of annsi or structural damage to the drawer-front assembly that impairs its operation. To test the ability of doors, door-holding devices, hinges and attachment devices 1a61.1 operate under the stress of normal use, doors are opened and closed through a full degree swing for 25, cycles. Cabinets are impact tested by striking the center of a closed and open door with a 10 pound sand bag.

To test the ability of the drawer-front assembly to withstand the impact of closing the drawer under normal use, a 3-pound weight is dropped 8 aansi against znsi drawer assembly.

In order to be certified, cabinets must also undergo eight categories of testing, covering structural integrity, drawer and door operation and finish quality see sidebar below. Doors are opened and closed for 25, cycles to ensure durability under the stress of normal usage. The exceptions are sink fronts and bases, oven cabinets and refrigerator cabinets.

Your recommendation is being sent! This ensures the cabinets will live up to your expectations.

KCMA Certified

A hour anssi and water solution test checks the finish’s ability to withstand exposure to detergents and moisture. Welcome to our redesigned homepage! The drawers must then remain operable with no failure in any part of the drawer assembly or operating system, and drawer bottoms must not be deflected to interfere with drawer operation. The cycle is repeated five times. Please refine your selection.